Each LUN is assigned to one controller, which is considered the owner, or the active primary controller, of a particular LUN. Push the Controller bottom panel toward the front to latch it to the side panels. This policy uses the SCSI2 reserve to lock the device to a single initiator path , and commands routed through any other path result in a reservation conflict. The other two paths are used if the preferred controller is not accessible by the host. This is not is in accordance with the current T10 standards for the persistent reservations command set, but preserves compatibility with the legacy implementation. The connector is keyed so that there is only one way to attach the harness to the connector. If you specify the -c flag, the command changes the driver selection to an alternate supported driver for the storage model.

Uploader: Dairg
Date Added: 4 July 2007
File Size: 18.5 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 7170
Price: Free* [*Free Regsitration Required]

DS family products interoperability matrix http: The last thing you need to do is reset the battery age back to zero.

Controller slides right out. I would not wish this on anyone. If you read enough IBM release notes, this text rdsc be familiar to you: Upgrading the drive firmware to FQ8 will prevent this problem. This simplifies zoning and improves performance.

Replace a Cache Controller Battery on an IBM DS4300

View all posts by David Maldonado. This is not is in accordance with the current T10 standards for the persistent reservations command set, but preserves compatibility with the legacy implementation.

See Also  INTEL DQ82536EP DRIVER DOWNLOAD

This policy prevents other initiators in the same host or on other hosts from accessing the device.

Initiators from other host systems are required to register before they can access the device. Notify me of new posts by email.

Techdocs: Instructions to convert DS disks from MPIO to AIX_fcparray(RDAC).

Reattach the battery access panel. This is in accordance with the current T10 standards for the persistent reservations command set.

Alternatively one can stop using the hdisks varyoff any VG with the disks and eliminate the -P flag to dss4300 into effect without a reboot. One zone contains an HBA port and controller port from controller A. Push the Controller bottom panel toward the front to latch it to the side panels. AIX multipath for DS The default settings on a DS with firmware The other zone contains a different HBA port and controller port from controller B.

This is done through the Storage Manager Client. And that is done rda going through the Storage Manager Client. You must connect the new battery harness to the two-pin connector on the Controller board. I usually wait a minute before bringing the Controller back online. PCM does not allow you to select an algorithm that could cause thrashing.

See Also  INTELR 82579V GIGABIT DRIVER

AIX MPIO and SDDPCM multipath options with DS,DS,DS 常见问题解答_百度文库

All disks of a storage model must be managed by the same driver. This configuration provides two paths to hdisks. In this example, failing Controller B will fail over all of its associated array groups to Controller A.

This policy uses the D4300 reserve to lock the device to a single initiator pathand commands routed through any other rdav result in a reservation conflict. The other two paths are used if the preferred controller is not accessible by the host.

Notify me of follow-up comments by email. The bottom panel then slides out and can be tilted up and away.

The other controller is considered as an alternate, or passive secondarycontroller. Once Controller B is failed. Reconnect the fiber and network exactly as it was before. Each LUN is assigned to one controller, which is considered the owner, or the active primary controller, of a particular LUN. Three on each side.